Table 4.3       Noise
Monitoring Parameters, Duration and Frequency
| 
   Contract No.  | 
  
   Monitoring Stations  | 
  
   Parameters[2]  | 
  
   Duration  | 
  
   Frequency  | 
  
   Measurement  | 
  
  |
| 
   ND/2019/06  | 
  
   CP-FLN-NMS1[3]  | 
  
   L10(30 min.) dB(A) L90(30 min.) dB(A) Leq(30 min.)dB(A)  (as six
  consecutive Leq, 5min readings)  | 
  
   0700-1900 hours on normal weekdays  | 
  
   Once per
  week  | 
  
   Façade  | 
  
  |
| 
   ND/2019/04  | 
  
  ||||||
| 
   ND/2019/05  | 
  
  ||||||
| 
   CP-FLN-NMS2[4]  | 
  
  ||||||
| 
   ND/2019/01  | 
  
   CP-KTN NMS2[5]  | 
  
   Free-field[1]  | 
  
  ||||
| 
   CP-KTN NMS3[6]  | 
  
  ||||||
| 
   ND/2019/01  | 
  
   CP-KTN NMS5  | 
  
  |||||
| 
   ND/2019/02  | 
  
   CP-KTN-NMS6  | 
  
   Façade  | 
  
  
Remarks:
[1]: Correction of +3dB (A) for free-field measurement.
[2]:
A-weighted equivalent continuous sound pressure level (Leq). It is
the constant noise level which, under a given situation and time period,
contains the same acoustic energy as the actual time-varying noise level.
L10 is
the level exceeded for 10% of the time. For 10% of the time, the sound or noise
has a sound pressure level above L10. 
L90 is
the level exceeded for 90% of the time. For 90% of the time, the noise level is
above this level.
[3]: Since the distance between monitoring station and site boundary of
ND/2019/03 under EP-473/2013/A exceeds 300m, the monitoring station is not applicable
to ND/2019/03.
[4]: Since the
distance between monitoring station and site boundary of ND/2019/03 and ND/2019/04 under EP-473/2013/A exceeds 300m, the monitoring station is not
applicable to ND/2019/03 and ND/2019/04.
[5],[6]: Since
the distance between monitoring station and site boundary of ND/2019/03 under
EP-468/2013/A exceeds 300m, the monitoring station is not applicable to
ND/2019/03.